New method of mathematical correction of the results of analysis, obtained by inductively coupled plasma mass spectrometry, allowing the elimination of a double charged ions interference

T13N3

K.I. Chervyakovskii

A new method of mathematical correction of the results of analysis, obtained by inductively coupled plasma mass spectrometry, for elimination of a doubly charged ions interference based on the use the isotope signal registration in two spectrometer operation modes: in standard one and with using the collision cell was proposed. Mathematical correction of the results of arsenic determination in the model solutions was performed with the aid of two process: standard and proposed in this paper. The comparison of the results accuracy and repeatability was conducted.

Back to contents

Interpretation and simulation of negative ion mass spectra of some phosphorus organoelement compounds

Sorry, this entry is only available in Русский.

The «low-molecular» approach to identification of microorganisms by MALDI mass spectrometry

T13N3

B.L. Milman, Yu.Yu. Ilyasov, N.V. Lugovkina, A.A. Golovina1, A.V. Dmitriev

The new approach to microorganism identification is presented which includes the transformation of their MALDI mass spectra directed to decreasing mass scale by the order of magnitude and the use of the standard software for building mass spectral libraries of low-molecular compounds and library searches. The library of 728 transformed mass spectra of 182 strains for some Streptococcus species was built. With this library, the rate of true identification was estimated by cross-comparison between library mass spectra. The true identification rate is 84 % for three Streptococcus species that corresponds to the average trueness of species identification by MALDI as found in the literature. The proposed approach to identification can be considered as the method of choice for solving problems of bacteria identification.

Back to contents

A comparison of electrospray tandem mass spectra of some derivatives of sialic acid: ion trap and high resolution QqToF mass spectrometers

T13N2

A.O. Chizhov, A.M. Spirt1, N.Y. Savel’eva, L.O. Kononov

Using O-acetyl-N-acyl derivatives of O-methyl sialoside methyl esters it was shown that an ion trap and a hybrid analyzer (linear quadrupole — time-of-flight analyzer, reflectron) give comparable, though not identical secondary order mass spectra for the [M+Na]+ and [M+K]+ ions. A parallel use of an ion trap and a hybrid QqToF instrument makes possible to get information on fragmentation pathways of ions of sialic acid derivatives under collisional activation. In this case, a sequence of fragmentation may be established using an ion trap, whereas a QqToF instrument gives a possibility to reveal elemental composition of fragment ions quickly and unequivocally.

Back to contents

T13N2

Contents

 

81 Игорь Александрович Ревельский (к восьмидесятилетию со дня рождения)

 

Todua_Graf

83 Mass spectrometry of analytical derivatives. 2. “Ortho”
and “Para” effects in electron ionization mass spectra
of derivatives of hydroxy, mercapto and amino benzoic acids

N.G. Todua, A.I. Mikaia

 

Kozlov_Graf

95 Investigation of organic sulfides in the form of sulfonium salts
by “soft” ionization mass spectrometric methods

A.V. Kozlov, R.S. Borisov, V.G. Zaikin

 

Pavlov_Graf

103 Synthesis of ion-optical devices for transportation
of charged particle beams in mass spectrometers

V.V. Pavlov, N.K. Krasnova

 

Amelin_Graf

111 Features of determination of residual amounts
of chloramphenicol and tetracycline in food by high performance liquid
chromatography/high resolution quadrupole time-of-flight mass spectrometry

V.G. Amelin, N.M. Fedina, A.I. Korotkov

 

Shevlyakova_Graf

117 Detection of metabolites of flavonoids Epimedium in rats urine
by high performance liquid chromatography-high-resolution
tandem mass spectrometry

O.A. Shevlyakova, K.J. Vasil’yev, A.A. Ihalaynen,
A.M. Antokhin, V.F. Taranchenko, V.M. Goncharov,
A.V. Aksenov, D.A. Mitrofanov, I.A. Rodin, O.A. Shpigun

 

Raznikov_Graf

124 Disentangling of information about the structure
of biomolecules based on decomposition and separation
of two-dimensional charge distributions of ions

V.V. Raznikov, M.O. Raznikova, M.L. Pridatchenko

 

Kuleshov_Graf

132 Application of high-performance liquid chromatography / high 
resolution mass spectrometry for investigation 
of sodium 2,3-disulfanyl-1-propanesulfonate (unithiol) 
and products of its oxidation with hydrogen peroxide

D.O. Kuleshov, T.E. Berezkina, Y. V. Russkikh, E. N. Chernova,
Z. A. Zhakovskaya, S.V. Masyukevich, L.N. Gall, N.R. Gall

 

Chijov_Graf

139 A comparison of electrospray tandem mass spectra
of some derivatives of sialic acid: ion trap
and high resolution QqToF mass spectrometers

A.O. Chizhov, A.M. Spirt, N.Y. Savel’eva, L.O. Kononov

 

144 Информация о защищенных диссертациях по масс-спектрометрии

 

146 Памяти Анатолия Марковича Зякуна 

Application of high-performance liquid chromatography / high resolution mass spectrometry for investigation of sodium 2,3-disulfanyl- 1-propanesulfonate (unithiol) and products of its oxidation with hydrogen peroxide

T13N2

D.O. Kuleshov, T.E. Berezkina, Y. V. Russkikh, E. N. Chernova, Z. A. Zhakovskaya,
S.V. Masyukevich, L.N. Gall, N.R. Gall

High-performance liquid chromatography combined with high resolution mass spectrometry has been used to study soft oxidation of sodium 2,3-disulfanyl-1-propanesulfonate (unithiol) with hydrogen peroxide; reference peaks were identified for initial substance and reaction products. The possibility to use high-performance liquid chromatography with high resolution mass spectrometry for Sokolovsky thiol-disulphide test has been shown.

Back to contents

Disentangling of information about the structure of biomolecules based on decomposition and separation of two-dimensional charge distributions of ions 

T13N2

V.V. Raznikov, M.O. Raznikova, M.L. Pridatchenko Читать полностью

Detection of metabolites of flavonoids Epimedium in rats urine by high performance liquid chromatography-high-resolution tandem mass spectrometry

T13N2

O.A. Shevlyakova, K.J. Vasil’yev, A.A. Ihalaynen, A.M. Antokhin, V.F. Taranchenko,
V.M. Goncharov, A.V. Aksenov, D.A. Mitrofanov, I.A. Rodin, O.A. Shpigun Читать полностью

Features of determination of residual amounts of chloramphenicol and tetracycline in food by high performance liquid chromatography/high resolution quadrupole time-of-flight mass spectrometry

T13N2

V.G. Amelin, N.M. Fedina, A.I. Korotkov Читать полностью

Synthesis of ion-optical devices for transportation of charged particle beams in mass spectrometers

T13N2

V.V. Pavlov, N.K. Krasnova Читать полностью