Том 13. Сводное содержание (2016)

 

3 Кирьянов Георгий Иосифович (к девяностолетию со дня рождения)

7 Алимпиев Сергей Сергеевич (к семидесятилетию со дня рождения)

9 Конёнков Николай Витальевич (к шестидесятипятилетию со дня рождения)

 Averin_graf

11 Static mass spectrographs of a new type 
using electric and magnetic fields which 
are homogeneous in Euler’ terms. II. 
High order double focusing conditions 
for two-cascade schemes

A.S. Berdnikov, I.A. Averin, Yu.K. Golikov

Lebedev_Graf

21 Chromatography/mass spectrometry in the study of aquatic chlorination of UV-filter avobenzone

K. Kalister, D. Dolenc, M. Sarakha, O.V. Polyakova, 
A.T. Lebedev, P. Trebše

 Sharafutdinova-Graf

27 Comparative analysis of binding of 
thiacalix[4]arene-monocrown-ethers 
with monovalent metal salts using 
maldi mass spectrometry

K. Kalister, D. Dolenc, M. Sarakha, O.V. Polyakova, 
A.T. Lebedev, P. Trebše

 Morozik_Graf

36 Prediction of electron ionization mass spectra of О-alkyl methylfluorothionophosphonates

D.R. Sharafutdinova, O.B. Bazanova, A.A. Murav’ev, 
S.E. Solov’eva, Z.A. Bredikhina, V.M. Babaev, I.S. Antipin

 Popov-Graf

44 Stereospecific fragmentation of starfish polyhydroxysteroids 
in electrospray ionization mass spectrometry

Yu.I. Morozik, A.V. Dudkin, Yu.V. Tкachuk, I.V. Rybal’chenko, R.V. Khatymov

Zenkevich_Graf

52 New possibilities of dimethylformamide dimethylacetal 
as derivatization agent for gas chromatography/mas spectrometry analysis

R.S. Popov, P.S. Dmitrenok

Berdnikov_Graf

62 On the impossibility of the double focus in combined electric 
and magnetic fields which are homogeneous in Euler’ terms

I.G. Zenkevich, T.I. Pushkareva

66 Памяти Вячеслава Васильевича Тахистова
68 Информация о защищенных диссертациях по масс-спектрометрии

 

81 Игорь Александрович Ревельский (к восьмидесятилетию со дня рождения)

 

Todua_Graf

83 Mass spectrometry of analytical derivatives. 2. “Ortho”
and “Para” effects in electron ionization mass spectra
of derivatives of hydroxy, mercapto and amino benzoic acids

N.G. Todua, A.I. Mikaia

 

Kozlov_Graf

95 Investigation of organic sulfides in the form of sulfonium salts 
by “soft” ionization mass spectrometric methods

A.V. Kozlov, R.S. Borisov, V.G. Zaikin

 

Pavlov_Graf

103 Synthesis of ion-optical devices for transportation 
of charged particle beams in mass spectrometers

V.V. Pavlov, N.K. Krasnova

 

Amelin_Graf

111 Features of determination of residual amounts
of chloramphenicol and tetracycline in food by high performance liquid 
chromatography/high resolution quadrupole time-of-flight mass spectrometry

V.G. Amelin, N.M. Fedina, A.I. Korotkov

 

Shevlyakova_Graf

117 Detection of metabolites of flavonoids Epimedium in rats urine 
by high performance liquid chromatography-high-resolution 
tandem mass spectrometry

O.A. Shevlyakova, K.J. Vasil’yev, A.A. Ihalaynen, 
A.M. Antokhin, V.F. Taranchenko, V.M. Goncharov, 
A.V. Aksenov, D.A. Mitrofanov, I.A. Rodin, O.A. Shpigun

 

Raznikov_Graf

124 Disentangling of information about the structure
of biomolecules based on decomposition and separation
of two-dimensional charge distributions of ions

V.V. Raznikov, M.O. Raznikova, M.L. Pridatchenko

 

Kuleshov_Graf

132 Application of high-performance liquid chromatography / high 
resolution mass spectrometry for investigation 
of sodium 2,3-disulfanyl-1-propanesulfonate (unithiol) 
and products of its oxidation with hydrogen peroxide

D.O. Kuleshov, T.E. Berezkina, Y. V. Russkikh, E. N. Chernova, 
Z. A. Zhakovskaya, S.V. Masyukevich, L.N. Gall, N.R. Gall

 

Chijov_Graf

139 A comparison of electrospray tandem mass spectra 
of some derivatives of sialic acid: ion trap 
and high resolution QqToF mass spectrometers

A.O. Chizhov, A.M. Spirt, N.Y. Savel’eva, L.O. Kononov

 

144 Информация о защищенных диссертациях по масс-спектрометрии

 

146 Памяти Анатолия Марковича Зякуна 

 

 

153 Волкович С.В. К семидесятипятилетию со дня рождения

 

 

155 Шарафутдинова Д.Р. К шестидесятипятилетию со дня рождения

 

 

156 О присуждении награды имени Курта Брюне 2016 г. в области масс-спектрометрии

 

 

 Milman_Graf

157 The «low-molecular» approach to identification
of microorganisms by MALDI mass spectrometry

B.L. Milman, Yu.Yu. Ilyasov, N.V. Lugovkina,
A.A. Golovina, A.V. Dmitriev

 

 

Kosevich_Graf

167 Mass spectrometric observation of charged nanoclusters
of silver with inclusion of hydrogen formed under reduction
of AgNO3 in ethylene glycol

O.A. Boryak, M.V. Kosevich, V.V. Chagovets,
V.S. Shelkovsky 

 

 

Antoshkin_Graf

176 Determination of the geographical region of growing
the coffee beans by gas chromatograph-combustion – isotope
ratio mass spectrometry

A.M. Antokhin, V.F. Taranchenko, S.V. Vasilevsky,
A.V. Aksenov, Ju. B. Aksenova, O.V. Kuznetsova,
I.V. Lapko, M.A. Glushkova

 

 

Chijov_Graf

183 Gas-phase fragmentation studies of biotinylated,
hexaethylene glycol-spacered oligosaccharides — molecular
probes — using electrospray mass spectrometry
on hybrid high-resolution mass spectrometer

A.O. Chizhov, D.A. Argunov, M.L. Gening,
E.V. Sukhova, E.A. Khatuntseva, A.A. Karelin,
B.S. Komarova,M.V. Orekhova, V.B. Krylov,
D.V. Yasunskii, Yu.E. Tsvetkov, N.E. Nifantiev

 

 

Terentev_Graf

193 Interpretation and simulation of negative ion mass spectra
of some phosphorus organoelement compounds

А.G. Terentyev, R.V. Khatymov, M.A. Lyogkov,
A.V. Dudkin, I.V. Rybal’chenko

 

 

Chervyakovskiy_Graf

203 New method of mathematical correction of the results
of analysis, obtained by inductively coupled plasma mass spectrometry,
allowing the elimination of a double charged ions interference

K.I. Chervyakovskii

 

 

 

217 Заикин В.Г. К семидесятипятилетию со дня рождения

 

219 О кандидате на избрание в почетные члены Всероссийского масс-спектрометрического общества (2016–2017)

 

Slundina_Graf

220 Tryptamine: reactive matrix for MALDI mass spectrometry

M.S. Slyundina, N.Yu. Polovkov, 
R.S. Borisov, V.G. Zaikin

 

Katina_Graf

225 Identification of regions in apomyoglobin 
which form intermolecular interactions in amyloid 
aggregates using high-performance mass spectrometry

N.S. Katina, M.Yu. Suvorina, E.I. Grigorashvili, 
V.V. Marchenkov, N.A. Ryabova, A.D. Nikulin, A.K. Surin

 

 Raznikov_Graf

235 Possibilities for energy pumping in radio-frequency quadrupole 
by shifted supersonic gas jet. 
Part I. Accelerated and excited atoms transmission

V.V. Raznikov, V.V. Zelenov, E.V. Aparina, 
A.R. Pikhtelev, I.V. Sulimenkov

 

 Baigildiev_Graf

241 Determination of methylphosphonic acid in human blood 
plasma by high-performance liquid chromatography 
tandem mass spectrometry

T.M. Baygildiev, I.A. Rodin, A.N. Stavrianidi, 
A.V. Braun, O.A. Shpigun, I.V. Rybalchenko

 

 Shevyrin_Graf

247 Chemical structure elucidation of gas 
chromatographic artifact of synthetic cannabinoid 
N-(1-carbamoyl-2-methylpropyl)-1-(cyclohexylmethyl)-1H-indazol-3-carboxamide 
by means of high resolution mass spectrometry

V.A. Shevyrin

 

 Milman_Graf

252 The comparison between «low-molecular» and 
conventional approaches to species identification 
of bacteria by MALDI mass spectrometry

B.L. Milman, V.V. Gostev, A.V. Dmitriev

 

 Sulemenkov_Graf

258 Study of gaseous sample ionization by excited 
particles formed in glow discharge using high 
resolution orthogonal acceleration time-of-flight 
mass spectrometer

I.V. Sulimenkov, V.S. Brusov, V.V. Zelenov, 
M.G. Skoblin, V.V. Filatov, A.R. Pikhtelev, V.I. Kozlovskii

 

 sysoeva

268 A new approach to increase the resolution 
of the mass spectrometer with wedge-shaped reflectors

E.A. Sysoeva, A.V. Spakhov, Alexander A. Sysoev

 

A new approach to increase the resolution of the mass spectrometer with wedge-shaped reflectors

T13N4

E.A. Sysoeva, A.V. Spakhov, Alexander A. Sysoev

 The paper describes the investigation of ion-optical properties of a laser TOF mass spectrometer including two successively positioned wedge-shaped ion mirrors. Some specific properties of the configuration of ion trajectories near their reflection in the second ion reflector have been found. The dependence of aberrations on the ion energy was acquired the toothed shape for the resolution of the analyzer higher than 3000-5000. An approximation of the dependence gave a polynom of the 15-th degree. The calculation of polynomial coefficients showed a great contribution into the duration of ion packets for aberrations of higher order. The discovered features allowed us to suggest a way of local correction of nearby trajectories in the full flow of ions. By correcting the local motion of individual groups of ions it was possible to reduce temporary aberration up to 1−1.6 ns depending on the ion energy. For the time of ion flight ~ 35 μs, such duration limits the resolution of the analyzer by a value not less than 10000. The real length of the ion drift path was about 30 cm. The total overall sizes of the ion-optical system were ~ 24 cm × 19 cm × 5 cm.

Back to contents

T13N4

Contents

 

217 Заикин В.Г. К семидесятипятилетию со дня рождения

 

219 О кандидате на избрание в почетные члены Всероссийского масс-спектрометрического общества (2016–2017)

 

Slundina_Graf

220 Tryptamine: reactive matrix for MALDI mass spectrometry

M.S. Slyundina, N.Yu. Polovkov,
R.S. Borisov, V.G. Zaikin

 

Katina_Graf

225 Identification of regions in apomyoglobin
which form intermolecular interactions in amyloid
aggregates using high-performance mass spectrometry

N.S. Katina, M.Yu. Suvorina, E.I. Grigorashvili,
V.V. Marchenkov, N.A. Ryabova, A.D. Nikulin, A.K. Surin

 

 Raznikov_Graf

235 Possibilities for energy pumping in radio-frequency quadrupole
by shifted supersonic gas jet.
Part I. Accelerated and excited atoms transmission

V.V. Raznikov, V.V. Zelenov, E.V. Aparina,
A.R. Pikhtelev, I.V. Sulimenkov

 

 Baigildiev_Graf

241 Determination of methylphosphonic acid in human blood
plasma by high-performance liquid chromatography
tandem mass spectrometry

T.M. Baygildiev, I.A. Rodin, A.N. Stavrianidi,
A.V. Braun, O.A. Shpigun, I.V. Rybalchenko

 

 Shevyrin_Graf

247 Chemical structure elucidation of gas
chromatographic artifact of synthetic cannabinoid
N-(1-carbamoyl-2-methylpropyl)-1-(cyclohexylmethyl)-1H-indazol-3-carboxamide
by means of high resolution mass spectrometry

V.A. Shevyrin

 

 Milman_Graf

252 The comparison between «low-molecular» and
conventional approaches to species identification
of bacteria by MALDI mass spectrometry

B.L. Milman, V.V. Gostev, A.V. Dmitriev

 

 Sulemenkov_Graf2

258 Study of gaseous sample ionization by excited
particles formed in glow discharge using high
resolution orthogonal acceleration time-of-flight
mass spectrometer

I.V. Sulimenkov, V.S. Brusov, V.V. Zelenov,
M.G. Skoblin, V.V. Filatov, A.R. Pikhtelev, V.I. Kozlovskii

 

 sysoeva

268 A new approach to increase the resolution
of the mass spectrometer with wedge-shaped reflectors

E.A. Sysoeva, A.V. Spakhov, Alexander A. Sysoev

Study of gaseous sample ionization by excited particles formed in glow discharge using high resolution orthogonal acceleration time-of-flight mass spectrometer

T13N4

I.V. Sulimenkov, V.S. Brusov, V.V. Zelenov, M.G. Skoblin, V.V. Filatov,
A.R. Pikhtelev, V.I. Kozlovskii

The experimental results of mass spectral analysis of volatile organic compounds in gaseous sample using a new designed of the ion source with Penning ionization by excited metastable atoms of noble gas are presented. To analyze gas flow profile effect on the metastable atom transfer and the reaction efficiency, gas dynamic simulation of the reagent gas flow profile from the discharge zone to the ionization region was performed by ANSYS software. The n-octane and toluene samples diluted with helium at 100 ppb mole concentration were used for our experiments. The resulting mass spectra of n-octane and toluene samples contain far more intensive molecular ions in comparison to the n-octane and toluene electron ionization mass spectra from NIST database. The sensitivity of 5 ions per 1 pg and 130 ions per 1 pg was achieved for n-octane and toluene molecular ions using the developed ion source combined with our mass spectrometer. The corresponding detection limits are 2.3 pg s−1 and 0.08 pg s−1 for n-octane and toluene molecular ions. The detection limit for the reported ion source was considered theoretically.

Back to contents

The comparison between «low-molecular» and conventional approaches to species identification of bacteria by MALDI mass spectrometry

T13N4

B.L. Milman, V.V. Gostev, A.V. Dmitriev

 

The new approach to bacteria identification which uses the standard software for building mass spectral libraries of low-molecular compounds and for corresponding library searches, is compared to the conventional approach based on the commercial Biotyper software and database. The results are obtained for the random sample of 100 mass spectra of 25 strains of S. pyogenes, S. dysgalactiae subsp. equisimilis and S. anginosus. The spectra were sampled from the database of 728 mass spectra of 182 strains for some Streptococcus species. Both approaches were proved to result in the similar identification as 80–88 % of true outcomes. For similar reference mass spectra and the same identification criteria, the identification results were very close to each other as 24 agreements for 25 strains. This is the result from that different estimations of the mass spectral similarity included in programs under the comparison lead to the correlation of similarity indicators. A difference of identification results is mainly due to not the same reference databases and also different identification criteria.

Back to contents

Chemical structure elucidation of gas chromatographic artifact of synthetic cannabinoid N-(1-carbamoyl-2-methylpropyl)-1-(cyclohexylmethyl)-1H-indazol-3-carboxamide by means of high resolution mass spectrometry

T13N4

V.A. Shevyrin

Synthetic cannabinoids are the most popular psychoactive compounds within illegal market. In a course of gas chromatographic determination, some synthetic cannabinoids undergo chemical transformations due to their thermal interaction with chromatographic system. The present paper is devoted to structure elucidation of gas chromatographic artifact formed from synthetic cannabinoid N-(1-carbamoyl-2-methylpropyl)-1-(cyclohexylmethyl)-1H-indazol-3-carboxamide as a result of dehydratation of its terminal carbamoyl moiety. Structure of the artifact was determined by means of high resolution mass spectrometry.

Back to contents

Determination of methylphosphonic acid in human blood plasma by high-performance liquid chromatography tandem mass spectrometry

T13N4

T.M. Baygildiev, I.A. Rodin, A.N. Stavrianidi, A.V. Braun, O.A. Shpigun, I.V. Rybalchenko

 Using high performance liquid chromatography combined with tandem mass spectrometric detection, an approach for the determination of the most stable nerve agent biomarker, methylphosphonic acid, in human blood plasma has been developed. The proposed method is based on the derivatization reaction of methylphosphonic acid with p-bromophenacyl bromide. Optimization of conditions for human plasma sample preparation, mass spectrometric detection conditiones and gradient elution program has been performed. The proposed approach has demonstrated satisfactory reproducibility and selectivity of the determination, limit of detection for methylphosphonic acid in human plasma was 3 ng ml−1.

Back to contents

Possibilities for energy pumping in radio-frequency quadrupole by shifted supersonic gas jet. Part I. Accelerated and excited atoms transmission

T13N4

V.V. Raznikov, V.V. Zelenov, E.V. Aparina, A.R. Pikhtelev, I.V. Sulimenkov

 

Generation of the ion beam and its transmission into a mass analyzer is one of the central problems in mass spectrometry. The use of narrowly directed supersonic gas jet has a number of advantages in comparison with other ways of sampling. The aim of the work is to confirm the declared earlier properties of the jet formed at the output of cylindrical channel when the free path length of gaseous atoms at the beginning of the channel is comparable with the channel diameter. The paper describes ability of such supersonic jet to conserve an additional energy of the jet gas atoms. Significant influence of the temperature of the gas flow on the yield of cyclohexane fragment ions was found, cyclohexane being an admixture in the noble gas jet passing through the electron ionization ion source. Possibility to obtain a stream of metastable electronically excited atoms inside the jet is also shown. The results of the work confirm an availability of the supersonic gas jet to design a high efficiency ion source inside radio-frequency quadrupole at the input of the mass analyzer.

Back to contenrs

Identification of regions in apomyoglobin which form intermolecular interactions in amyloid aggregates using high-performance mass spectrometry

T13N4

N.S. Katina, M.Yu. Suvorina, E.I. Grigorashvili, V.V. Marchenkov, N.A. Ryabova, A.D. Nikulin,
A.K. Surin

 Formation of amyloid aggregates in human organs and tissues causes the development of incurable diseases. However experimental studies of the mechanism of amyloid formation by proteins as well as structural characteristics of amyloids are complicated because of heterogeneity and high molecular weight of the aggregates. We have used limited proteolysis and mass spectrometry for identification of regions in the polypeptide chain of apomyoglobin which give rise to intermolecular interactions in amyloid structures. The methods of tandem mass spectroscopy have allowed us to identify regions in the polypeptide chain of myoglobin which form the core of amyloid structures. It is shown that the main structural elements for the formation of the core of amyloid fibrils in myoglobin are regions from amino acid region 60 through 90 and from 97 through 124. These areas coincide well with the theoreticall prediction. The approach has made it possible to obtain important data on the structure of protein molecules in aggregates and on conformational rearrangements of apomyoglobin upon amyloid formation.

Bact to contents

Was published in the new issue of the magazine «Mass spectrometry» T. 13 number 4 (2016)

Sorry, this entry is only available in Русский.